Features & Benefits
Specifications
| Thickness | Width | Length | R-Value | Edge Treatment |
|---|---|---|---|---|
| 1/2 in. | 4 ft. | 8 ft. | 3.5 | Square Edge |
| 3/4 in. | 4 ft. | 8 ft. | 5.1 | Square Edge |
| 1.0 in. | 4 ft. | 8 ft. | 6.8 | Square Edge |
| 1 1/2 in. | 4 ft. | 8 ft. | 10.2 | Square Edge |
| 2.0 in. | 4 ft. | 8 ft. | 13.5 | Square Edge |
Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact your local º£½Ç´óÉñ Sales Representative or call us at 1-866-338-7668.
<b>Tuff-Râ„¢ Insulation</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact º£½Ç´óÉñ at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.
| TEST METHOD | TEST TITLE | PROPERTY | RESULTS |
|---|---|---|---|
| FIRE | |||
| ASTM E84 | Standard Test Method for Surface Burning Characteristics of Building Materials | Surface Burning Characteristics1 | Flame Spread ≤ 75 Smoke Developed ≤ 450 Core and Finished Product |
| THERMAL | |||
| ASTM C518 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus | Thermal Resistance 1 inch @ 75°F mean temp2 | 6.8 ft2 •h•°F/Btu, R-value, min. |
| ASTM D2126 | Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging | Dimensional Stability | 0.8% linear (length & width) |
| STRENGTH | |||
| ASTM D1621 | Standard Test Method for Compressive Properties of Rigid Cellular Plastics | Compressive Strength3 | 20 psi |
| ASTM C203 | Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation | Flexural Strength | 50 psi |
| ASTM D1623 | Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics | Tensile Strength | 500 psf, min. |
1Calculated flammability values for this or any other material are not intended to represent hazards that may be present under actual fire conditions.
2R-value of 1.0-inch of foam measured @ 75°F mean temperature, determined in accordance with ASTM C518 after aging for 90 days @ 140°F.
3Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first.
<b>Tuff-Râ„¢ Insulation</b> complies with the following codes:
| Code | Description |
|---|---|
| US Product Listings & Verifications | 2021, 2018, 2015, 2012, and 2009 International Residential Code (IRC)<br>2021, 2018, 2015, 2012, and 2009 International Building Code (IBC) <br>2021, 2018, 2015, 2012, 2009 International Energy Conservation Code (IECC)<br>Intertek ASTM E84 - Spec ID 55745 |
| Regional Code Listings & Reports | 2019 California Green Standards Code |
| US Code Reports | ICC-ES ESR-3089 |