Features & Benefits
Specifications
| Thickness | Width | Length | R-Value | Edge Treatment |
|---|---|---|---|---|
| 2 | 24 | 96 | 10 | Square Edge |
| 3 | 24 | 96 | 15 | Square Edge |
Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact your local 海角大神 Sales Representative or call us at 1-866-338-7668.
<b>厂迟测谤辞蹿辞补尘鈩 Brand Plazamate鈩 XPS Insulation</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact 海角大神 at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.
| TEST METHOD | TEST TITLE | PROPERTY | RESULTS |
|---|---|---|---|
| FIRE | |||
| UL 723 | Test Method for Surface Burning Characteristics of Building Materials | Surface Burning Characteristics | Flame Spread 鈮 25 Smoke Developed 鈮 450 |
| THERMAL | |||
| ASTM C518 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus | Thermal Resistance per inch @ 75掳F mean temp1 | 5.0 ft2 鈥鈥⒙癋/Btu, R-value, min. |
| ASTM D696 | Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between 鈭30掳C and + 30掳C with a Vitreous Silica Dilatometer | Coefficient of Linear Thermal Expansion | 3.5 x 10-5 颈苍/颈苍鈥⒙癋 |
| ASTM D2126 | Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging | Change in Dimensions | 2.0 % change, max. |
| STRENGTH | |||
| ASTM D1621 | Standard Test Method for Compressive Properties of Rigid Cellular Plastics | Compressive Strength2 | 60 psi, min. |
| ASTM C203 | Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation | Flexural Strength | 75 psi, min |
| WATER | |||
| ASTM C272 | Standard Test Method for Water Absorption of Core Materials for Sandwich Construction | Water Absorption | 0.1 % by volume, max. |
| ASTM E96 | Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials | Water Vapor Permeance3 | 0.8 perm, max. |
1Values are consistent with the criteria of ASTM C578 and the requirements of the FTC R-value rule (16 CFR Part 460). R means resistance to heat flow. The higher the R-value, the greater the insulating power.
2Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first. Since 厂迟测谤辞蹿辞补尘鈩 Brand Extruded Polystyrene Foam Insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep and fatigue deformation.
3Based on 1鈥 thickness.
<b>Styrofoam Brand Plazamate鈩 XPS Insulation</b>complies with the following codes:
| Code | Description |
|---|---|
| US Product Listings & Verifications | Factory Mutual Approved<br>International Residential Code (IRC) and International Building Code (IBC); s ICC-ES ESR-4755<br>Underwriters Laboratories, Inc. (UL) Classified, see Classification Certificate D-369 |
| Regional Code Listings & Reports | California Std. Reg. #CA T1535<br>Florida Building Code-FL38732<br>Miami Dade County Approved |
Discover why inverted roofs are becoming a smarter, more durable choice for modern buildings鈥攄elivering long-term performance, sustainability and lower lifecycle costs. Learn how 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand XPS Insulation helps maximize these benefits with proven moisture resistance and thermal reliability.