海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Highload 100 XPS Insulation

Subfloor Thermal Insulation for Low-Temperature Applications<br>U.S. HFC Regulation Compliant Formulation

<br><b>海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Highload 100 Extruded Polystyrene (XPS) Insulation</b> is a closed-cell foam insulation designed for demanding applications such as low-temperature (freezer floor) applications, highways, airport runways, bridge abutments, parking decks, utility lines, and ice rinks. With a compressive strength of 100 psi (690 kPa), it offers exceptional moisture resistance and R-value retention. <br><br><b>厂迟测谤辞蹿辞补尘鈩 Brand Highload Insulation</b> products are engineered to resist compressive creep and fatigue, ensuring sustained compressive strength over time. Like all 厂迟测谤辞蹿辞补尘鈩 Brand insulation products, <b>Highload 100 XPS Insulation</b> is known for its durability, versatility, and reusability, making it a preferred choice for a wide range of high-load applications.
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Standard Sizes

Thickness Width Length R-Value Edge Treatment
1.5 in. 2 ft. 8 ft. 7.5 Square Edge
2 in. 2 ft. 8 ft. 10 Square Edge
3 in. 2 ft. 8 ft. 15.0 Square Edge

Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact your local 海角大神 Sales Representative or call us at 1-866-338-7668.

 
 
 

Testing

<b>厂迟测谤辞蹿辞补尘鈩 Brand Highload 100 XPS Insulation</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact 海角大神 at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD TEST TITLE PROPERTY RESULTS
FIRE
UL 723 Test Method for Surface Burning Characteristics of Building Materials Surface Burning Characteristics Flame Spread 鈮 25
Smoke Developed 鈮 450
THERMAL
ASTM C518 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus Thermal Resistance per inch, @ 75掳F mean temp.1 5.0 ft2
鈥鈥⒙癋/Btu, R-value, min.
ASTM D696 Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between 鈭30掳C and + 30掳C with a Vitreous Silica Dilatometer Coefficient of Linear Thermal Expansion 3.5 x 10-5
颈苍/颈苍鈥⒙癋
ASTM D2126 Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging Change in Dimensions 2.0 % change, max.
STRENGTH
ASTM D1621 Standard Test Method for Compressive Properties of Rigid Cellular Plastics Compressive Strength2 100 psi, min.
ASTM D1622 Standard Test Method for Compressive Properties of Rigid Cellular Plastics Compressive Modulus (typical) 3,700 psi
ASTM C203 Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation Flexural Strength 100 psi, min
WATER
ASTM C272 Standard Test Method for Water Absorption of Core Materials for Sandwich Construction Water Absorption 0.1 % by volume, max.
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Permeance3 0.8 perm, max.

1Values are consistent with the criteria of ASTM C578 and the requirements of the FTC R-value rule (16 CFR Part 460). R means resistance to heat flow. The higher the R-value, the greater the insulating power.

2Vertical compressive strength is measured at 5 percent deformation or at yield, whichever occurs first. Since Styrofoam insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep. For static loads, 3:1 is suggested. For dynamic loads, call 1-866-583-2583 for safety factor recommendation.

3Based on 1鈥 thickness.

 
 
 
 
 
 
 
 
 
 
 
 

Code Compliance

<b>厂迟测谤辞蹿辞补尘鈩 Brand Highload 100 XPS Insulation</b> complies with the following codes:

Code Description
US Product Listings & Verifications Factory Mutual Approved<br>International Residential Code (IRC) and International Building Code (IBC); see ICC-ES ESR-4755<br>Underwriters Laboratories, Inc. (UL) Classified, see Classification Certificate D-369
Regional Code Listings & Reports California Std. Reg. #CA T1535
 
 
 
 
 
 
 
 
 
 
 
 

FAQ

Can 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Extruded Polystyrene Foam Insulation be used in railway bed applications?
Yes. Railroad facilities such as track, at grade crossings, switching yards, etc. are at risk of frost damage if the underlying soils are susceptible to frost heave and spring breakup. Engineers have found 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Highload 40, 60 and 100 Extruded Polystyrene XPS Insulation, when placed beneath these railroad facilities, reduces the potential for damaging effects of frost heave or spring thaw weakening.

The thickness and width of the 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Extruded Polystyrene XPS Insulation used for a particular roadway can be determined based on figures and computer models provided by 海角大神TM. The variables needed are average frost penetration in feet/m, freezing degree days for a particular location, roadway cross section materials and thickness, soil type, etc. If you have a particular situation using 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Highload XPS Insulation, please call 1-833-338-7668 for calculations.

Can 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Extruded Polystyrene Foam Insulation be used in roadway applications?
Yes. Whenever roadway underlying soils are susceptible to frost, roadways will suffer frost heaving and spring breakup. The damaging effects of this frost action play havoc with traffic on major arteries as well as posing a monumental expense for repair year in and year out.

海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Highload 40, 60 and 100 Extruded Polystyrene XPS Insulation has been successfully used to reduce frost and thaw damage on countless roadways in Canada, the United States, Japan and throughout Europe. When properly installed between the subsoil and gravel base. 厂迟测谤辞蹿辞补尘鈩 Brand Highload Insulation products reduce heat loss from the frost susceptible sub-grade so that frost heaving and spring breakup are held at bay.

The thickness and width of the 厂迟测谤辞蹿辞补尘鈩 Brand XPS Insulation used for a particular roadway can be determined based on figures and computer models provided by 海角大神TM. The variables needed are average frost penetration in feet/m, freezing degree days for a particular location, roadway cross section materials and thickness, soil type, etc. If you have a particular situation using 厂迟测谤辞蹿辞补尘鈩 Brand Highload Insulation, please call 1-833-338-7668 for calculations.

What is the compressive modulus of海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Extruded Polystyrene Foam Insulation?
Compressive modulus is a measure of the force required to produce a given deflection as measured in the fraction of deflection of the original sample鈥檚 thickness. Products with a higher compressive modulus are 鈥渟tiffer鈥 and require more force to produce a deflection in the product.

A table of typical compressive modulus values for various grades of 厂迟测谤辞蹿辞补尘鈩 Brand Extruded Polystyrene Foam Insulation made in Canada can be found below:

Product Compressive Modulus
厂迟测谤辞蹿辞补尘鈩 Highload 40 XPS Insulation 1,400 psi (9,650 kPa)
厂迟测谤辞蹿辞补尘鈩 Highload 60 XPS Insulation 2,200 psi (15,170 kPa)
厂迟测谤辞蹿辞补尘鈩 Highload 100 XPS Insulation 3,700 psi (25,510 kPa)

Which 海角大神 Performance聽Building Solutions products can be used in lightweight fill applications?
海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Square Edge XPS Insulation, 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Highload 40, 60 and 100 Extruded Polystyrene (XPS) Insulations are recommended for use in lightweight applications. Care must be taken to select the appropriate insulation from this list.
What are the ASTM C578 classifications for 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Extruded Polystyrene Foam Insulation products?
The ASTM C578 classifications for 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Extruded Polystyrene (XPS) Insulation products are as shown below:
ASTM C578 Types 海角大神 Products
Type X

厂迟测谤辞蹿辞补尘鈩 Brand Residential Sheathing 厂迟测谤辞蹿辞补尘鈩 Brand Cavitymate鈩 XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Panel Core 20

Type IV

厂迟测谤辞蹿辞补尘鈩 Brand Tongue and Groove Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Square Edge XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Scoreboard XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Deckmate鈩 Plus XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Deckmate鈩 Plus FA XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Cavitymate鈩 Plus XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Cavitymate鈩 Ultra XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Panel Core 30 Freezermate鈩 XPSInsulation 厂迟测谤辞蹿辞补尘鈩 Brand Ag BoardXPS Insulation

Type VI

厂迟测谤辞蹿辞补尘鈩 Brand Highload 40 XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Panel Core 40 XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Roofmate鈩 XPS Insulation

Type VII

厂迟测谤辞蹿辞补尘鈩 Brand Highload 60 XPS Insulation 厂迟测谤辞蹿辞补尘鈩 Brand Plazamate鈩 XPS Insulation

Type V

厂迟测谤辞蹿辞补尘鈩 Brand Highload 100 XPS Insulation

What are the ballast requirements for perimeter areas or penetrations in Protected Membrane Roof (PMR) assemblies?
Certain areas of the protected membrane roof (PMR) insulation require additional ballast to overcome high wind loads and to restrain the foam from floating during heavy rain storms. This ensures that individual stones cannot migrate to below the foam and abrade the membrane. Areas needing such additional ballasting are:

Perimeter Edge of Insulation: which is an 8-foot-wide swath running along the perimeter edge of the roof insulation (and which includes any insulation adjacent to higher walls).

Penetrations Through Insulation: which are four-foot-wide swaths running around any roof insulation penetrations which exceed 4 feet in any direction, such as skylights, expansion joints, equipment pads, etc.

Corners: where arrays of concrete pavers are required in higher wind zones or with low parapet walls. These requirements are consistent with both the ANSI/SPRI RP-4 Ballast Design Guide (the procedure required by the International Building Code) and Factory Mutual requirements (Factory Mutual Property Loss Prevention Data Sheet 1-29 Page 18).

For more information, download Tech Solutions 508.3: Ballast Design Guide for PMR Systems (43-d100241). Call 1-833-338-7668 for ballast design information in Canada

What 海角大神 products are ENERGY STAR qualified?
The following 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Extruded Polystyrene XPS Insulation products have obtained ENERGY STAR certification: 聽Scoreboard, Square Edge, Tongue & Groove, Highload 40, Highload 60, and Residential Sheathing. Look for the ENERGY STAR logo on the product unit label. For more information, please visit:聽ENERGY STAR.
Can 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Highload products be tapered?
Yes. 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Highload products(40, 60 and 100) can be tapered in a manner similar to 海角大神鈩 厂迟测谤辞蹿辞补尘鈩 Brand Deckmate鈩 Plus FA Extruded Polystyrene XPS Insulation. The fabricator may need to adjust the cutting (tapering) speed to account for the higher density of these products.
 
 
 
 
 
 
 
 
 
 
 
 