海角大神

海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound

Vapor-Permeable Flashing Material for Commercial Wall Substrates

liquidarmor-fj-product-logo-image1.jpg
liquidarmor-fj-product-logo-image2.jpg
liquidarmor-fj-product-logo-image3.jpg

海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound

Vapor-Permeable Flashing Material for Commercial Wall Substrates

<br><b>海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound</b> is a brush or trowel-applied, vapor-permeable elastomeric flashing material. It combines the functions of both flashing and joint compound into a single unique product that is an integral part of the <b>海角大神鈩 础谤尘辞谤奥补濒濒鈩 System</b>.
 
 
 
 
 
 

Features & Benefits 

 
 
 
 
 
 

Specifications

 
 
 

Standard Sizes

Unit Unit Size Units per Case Cases per Pallet Units per Pallet
Sausage 20 oz 16 50 800
 
 
 

Testing

<b>海角大神鈩 LiquidArmor鈩 FJ</b> exhibits physical properties as indicated when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact 海角大神 at 1-833-338-7668 when additional guidance is required for writing specifications that include this product

TEST METHOD TEST TITLE PROPERTY RESULTS
STRENGTH
ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers鈥擳ension Tensile 215 psi
ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers鈥擳ension Elongation at Break 400%
ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers鈥擳ension Recovery (held at 300% elongation) >92%
ASTM D2240 Standard Test Method for Rubber Property鈥擠urometer Hardness Hardness 69 Shore A
ADHESION
ASTM D4541 Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers Adhesion Strength - Exterior Gypsum Delaminates fiberglass topsheet
ASTM D903 Standard Test Method for Peel or Stripping Strength of Adhesive Bonds Peel Strength 19 lbf/in (aluminum) Cohesive Failure
ASTM C794 Standard Test Method for Adhesion-in-Peel of Elastomeric Joint Sealants Adhesion-in-Peel 19.5 lbf/in (mortar)
FIRE
NFPA 285 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components Flame Propagation PASS Multiple Assemblies
AIR
ASTM 2178 Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials Air Penetration Resistance 0.0002 cfm/ft2 @ 75 Pa (1.57 psf)
Tappi T-460 Air resistance of paper (Gurley method), Test Method Air Penetration Resistance >10,000 sec/100 cc
ASTM E2357 Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies Wall Assembly Air Penetration Resistance <0.04 cfm/ft2 @ 75 Pa
ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen Wall Assembly Air Penetration Resistance <0.04 cfm/ft2 @ 75 Pa
WATER
AATCC 127 Test Method for Water Resistance: Hydrostatic Pressure Water Penetration Resistance >1000 cm
ASTM E96 Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials Water Vapor Transmission 14 @ 35 mils Method B perms
ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference Wall Assembly Water Penetration Resistance No leakage Tested to 15 psf
GENERAL
AAMA 714 Specification for Liquid Applied Flashing Used to Create a Water-Resistive Seal Around Exterior Wall Openings in Buildings Liquid Flashing Requirements PASS
ASTM D1970 Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection Nail Sealability PASS No leakage
ASTM C1305 Standard Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing Membrane Low Temperature Crack Bridging PASS No cracking at 30 mil thickness
ASTM C1250 Standard Test Method for Nonvolatile Content of Cold Liquid-Applied Elastomeric Waterproofing Membranes VOC <2 % (by wt.) 25-30 g/L
ASTM G155 Standard Practice for Operating Xenon Arc Lamp Apparatus for Exposure of Materials Ultraviolet Light Exposure (UV) 9 months, no change

NOTE:- Test results shown represent averages. Individual results may vary either above or below averages due to normal manufacturing variations, while continuing to meet product specifications.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FAQ

Can 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound be applied to damp surfaces?

LiquidArmor鈩 FJ can be applied to damp surfaces as long as there are not water droplets or a film of water on the surface.

Can 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound be used in window and door rough openings with the 海角大神鈩 础谤尘辞谤奥补濒濒鈩 System?

LiquidArmor鈩 FJ sealant is approved for use in window and door rough openings with the windowsill treated in conformance with the 础谤尘辞谤奥补濒濒鈩 System Installation Guide. This is subject to change as additional evaluations are completed. Installers may also use 海角大神鈩 DuraGard鈩 WD Self-Adhered Flashing Tape in window and door rough openings with the 础谤尘辞谤奥补濒濒鈩 System.

What is the theoretical coverage rate for 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

The theoretical coverage rate for a 20-ounce sausage of LiquidArmor鈩 FJ , when applied at 35 wet mils (+/- 5 mils) is:
2 inch wide......................36 lineal feet per sausage
3 inch wide......................24 lineal feet per sausage
6 inch wide......................12 lineal feet per sausage

How do I clean up tools after applying 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

Clean tools with mineral spirits, Naphtha, or citrus-based cleaners. DO NOT use water to clean tools. Please refer to installation guidelines located on the LiquidArmor鈩 FJ website.

What color is 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

LiquidArmor鈩 FJ Sealant is dark grey when applied and chemically cures to the same dark grey.

What are the approved storage conditions and temperatures for 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

LiquidArmor鈩 FJ should be stored in controlled conditions in a clean and relatively dry environment between 50鈦 to 80鈦 F (10鈦 to 27鈦 C). High temperatures and excessively high relative humidity may reduce the product shelf life.

What are the approved temperatures for applying 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

LiquidArmor鈩 FJ may be applied when substrate and ambient temperatures are above 20鈦 F (-6.6鈦 C) and rising. The substrate must not be covered with frost or ice. Do not install once the ambient or surface temperature exceeds 95鈦 F (35鈦 C).

What type of chemistry is 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

LiquidArmor鈩 FJ is a single component, vapor permeable, silyl-terminated polyether (STPE) flashing material that may be brush or trowel applied to joints and sheathing fasteners on the 海角大神鈩 础谤尘辞谤奥补濒濒鈩 System.

What is the shelf life of individual sausages of 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

Sausages of LiquidArmor鈩 FJ have a 15-month shelf life beginning from the date of manufacture printed on the individual sausage tubes. The 15-month shelf life applies to LiquidArmor鈩 FJ that is stored in controlled conditions in a clean and relatively dry environment between 50鈦 to 80鈦 F (10鈦 to 27鈦 C). High temperatures and excessively high relative humidity may reduce the product shelf life.

What are the approved locations that 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound can be used in conjunction with 海角大神鈩 础谤尘辞谤奥补濒濒鈩 System?

LiquidArmor鈩 FJ sealant is designed for use with the 海角大神鈩 础谤尘辞谤奥补濒濒鈩 System. LiquidArmor鈩 FJ

sealant may be applied with a brush or trowel over panel joints as well as all sheathing fastener heads. Through wall penetrations may be sealed using LiquidArmor鈩 FJ sealant in conformance with the 础谤尘辞谤奥补濒濒鈩 System Installation Guide.

Can 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound be exposed to precipitation immediately after installation? (AW-FAQ-44)

LiquidArmor鈩 FJ is a moisture-cured, silyl-terminated polyether (STPE) product that is non-water soluble and not susceptible to freezing and/or wash off when exposed to precipitation. LiquidArmor鈩 FJ can be applied to damp surfaces if there are not water droplets or a film of water on the surface.

Is there a warranty with 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

LiquidArmor鈩 FJ is an approved accessory item within the 海角大神鈩 础谤尘辞谤奥补濒濒鈩 System. When installed in accordance with the 海角大神鈩 础谤尘辞谤奥补濒濒鈩 System Install

Guide, the project may be eligible for the 海角大神鈩 础谤尘辞谤奥补濒濒鈩 System Components 10-Year Limited Warranty.

How is 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound currently packaged?

LiquidArmor鈩 FJ is packaged in 20-ounce sausages and are is shipped in a 16-pack carton.

What is the maximum in service temperature of 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

The maximum in service temperature of LiquidArmor鈩 FJ is 180鈦 F (82.2鈦 C).

What are the cure times for 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

LiquidArmor鈩 FJ has an initial skin time of 1-2 hours at 70鈦 F (21鈦 C) and 50% RH. and It is resistant to minor abrasion and water penetration around fasteners after 24 hours.
LiquidArmor鈩 FJ fully cures in approximately 14 days, depending on ambient conditions.
LiquidArmor鈩 FJ can be covered by building wraps, additional continuous insulation, or exterior cladding materials after 48 hours have elapsed from initial installation, depending on ambient conditions.

What is the required mil thickness for 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound?

When applied over panel joints, panel fasteners, and through wall penetrations with the 海角大神鈩 础谤尘辞谤奥补濒濒鈩 System, LiquidArmor鈩 FJ must be applied at 35 wet mils (+/- 5 mils).

Can 海角大神鈩 LiquidArmor鈩 FJ Flashing and Joint Compound be exposed to precipitation immediately after installation? (AW-FAQ-43)

LiquidArmor鈩 FJ is a moisture-cured, silyl-terminated polyether (STPE) product that is non-water soluble and not susceptible to freezing and/or wash off when exposed to precipitation. LiquidArmor鈩 FJ can be applied to damp surfaces if there are not water droplets or a film of water on the surface.

 
 
 
 
 
 
 
 
 
 
 
 

How can we help you?